General purposeSelf-coloring
HouseholdsSmall Appliances and white goods Vacuum CleanersElectrical components for civil and industrial applications
Packaged product should be protected from the atmosferic agents and stored out of direct sunlightNB: No Break/M: Matt - Digit following letter/M indicates increasing values of mattness
Properties
Test Condition
Test Methods
Units
General
Density
ISO 1183
g/cm3
1.04
Water Absorption
ASTM D 570
%
0.3
Rheological
Melt Flow Rate (MFR)
ISO 1133
g/10min
14
Mechanical
Tensile Strength
50mm/min
ASTM D 638
MPa
42
Strain at break
60
Flexural Strength
2mm/min
ASTM D 790
Flexural Modulus
2250
Izod Impact Strength Notched
+23°C - thickness 3.2 mm
ISO 180/4A
J/m
190
0°C - thickness 3.2 mm
125
-20°C - thickness 3.2 mm
100
-40°C - thickness 3.2 mm
90
+23°C - thickness 4 mm
ISO 180/1A
kJ/m²
-40°C - thickness 4 mm
8
Charpy Impact Strength, Notched
+23°C
DIN 53453
13
Unnotched
NB
-40°C
Rockwell Hardness
scale R
ISO 2039/2
R110
Thermal
Vicat Softening Tempreture
10 N - 120°C/h
ISO 306/A120
°C
107
50 N - 120°C/h
ISO 306/B120
102
Deflection temp. under load (annealed)
1.8 MPa - 120°C/h
ASTM D 648
101
Ceofficient of linear thermal expansion
ASTM D 696
10 -5/ºC
9
Thermal Conductivity
ASTM C 177
W/(Km)
0.17
Moulding Shrinkage
ISO 294.4
0.4-0.6
Flammability
Flame behavior
thickness 1.5 mm
UL 94
class
HB
Glow wire test
thickness 3 mm
IEC 60695-2-1
650
Electrical
Surface resistivity
dry
IEC 60093
ohm
10+14
Volume resistivity
ohm*cm
10+15
Dielectric strength
IEC 60243
kV/mm
30
Dielectric constant (relative permittivity)
1000 Hz - dry
IEC 60250
3.1
Dissipation factor
15*10-³